PoE Budget Calculator

Load, headroom, and verdict for PoE switches.

Technology and NetUpdated 2026-10-121 min read
PoE Budget Calculator
Total PoE watts the switch can supply.
Device draw; cameras often 7 to 12 W.
Total load
...
Headroom...
Verdict...

What it does

PoE switches carry a finite power budget shared across every camera, phone, and access point. Port counts mislead because the budget runs out before the ports do on fully loaded switches.

The tool above takes switch budget with device count and watts each. It returns total load with headroom and a within or over verdict, so shortfalls show before install day.

The defaults load 8 devices at 7 W on a 120 W budget: 56 W load, 64 W headroom, 46.7% used. Twelve 12 W devices instead draw 144 W and run 24 W over.

Classes follow IEEE 802.3af, at, and bt with roughly 15, 30, and 60 to 90 W per port at the source. Ethernet Alliance guidance matches the same three generations with class 8 near 71 W at the device.

How to use

  1. Enter switch PoE budget in watts.
  2. Enter powered device count.
  3. Enter watts per device.
  4. Read total load first.
  5. Read headroom beside it.
  6. Keep margin for inrush and growth.

Formula

Load = count x each. Headroom = budget - load. Used% = 100 x load / budget.
budget
Switch total PoE watts available.
load
Sum of device draws in watts.
headroom
Budget minus load; negative means over.

Totals pass while single ports fail: per port class caps and cable loss sit outside this line. Budget in device watts against source watts, and keep 20 to 30% headroom for startup surges.

Worked example

Example: 8 devices at 7 W on 120 W

Defaults: budget 120 W, 8 devices, 7 W each.

  1. Load: 8 x 7 = 56 W.
  2. Headroom: 120 - 56 = 64 W.
  3. Used: 100 x 56 / 120 = 46.7%.
  4. Verdict: within budget.
  5. Tool shows 56 W load, 64 W headroom.
  6. Twelve 12 W devices draw 144 W: 24 W over.

Reference table

Device plans on 120 W
PlanLoadResult
8 x 7 W56 W64 W headroom
4 x 25 W100 W20 W headroom
12 x 12 W144 W24 W over

Limits

  • Totals only; per port class separate.
  • Cable loss excluded from load.
  • Inrush exceeds steady state.
  • Passive nonstandard PoE differs.

Common mistakes

  • Counting ports instead of watts.
  • Mixing device and source watts.
  • Zero headroom at install.
  • Ignoring per port class caps.
  • Long thin cable runs unaccounted.

Try it yourself

Quick checks. Answers sit tucked under each question.

12 devices at 12 W on 120 W?

144 W load, over budget by 24 W.

4 devices at 25 W on 120 W?

100 W load with 20 W headroom.

Why keep headroom?

Inrush, growth, and warm switches eat margin.

Questions

What is PoE budget?

Total watts a switch can feed all powered devices together.

af vs at vs bt?

Roughly 15, 30, and 60 to 90 W per port at the source.

Device vs source watts?

Cable loss sits between; budget the source side.

How much headroom?

20 to 30% covers inrush and one more device.

Cameras typical draw?

Often 7 to 12 W, more with heaters and IR.

Budget passes but port fails?

Per port class caps bind first; move the device or port.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.